Whatsminer Error Code Guide

Whatsminer Error Code Guide

Whatsminer is a reliable miner when managed properly. Since miners run 24/7 for years and are constantly exposed to high heat, it’s very important to maintain proper temperature and keep the environment clean. Repair costs usually start from around $150, so it’s always better to take care of your machine before issues get worse.

Below are some of the most common Whatsminer error codes, with explanations of what they mean, the possible causes, and recommended solutions.

Error codeDescriptionRecommended Solution
110Fan in (front)detect speed error-Check the front fan connection
-Replace the front fan
111Fan out (exhaust end)detect speed error-Check the exhaust end fan connection
-Replace the exhaust end
130Fan in (front) speed error-Check the front fan connection
-Replace the front fan
131 Fan out (exhaust end)speed error-Check the exhaust end fan connection
-Replace the exhaust end
140Fan speed is too high-Check the environment temperature
-Use compressed air to remove dust from the miner and hashboard
200 – 201Power probing error, no power found-Replace using the correct PSU model
203, 204Power protecting , Power current error-Check and monitor the temperature of the miner and hashboard
205Power current error-Inspect the PSU connection for stability
206, 207Power input voltage is low
Power input current protecting
-Ensure stable power supply and proper input voltage
-Replace the faulty PSU
210Power error status-Verify power failure code status
213Power input voltage and current do not match the power-Replace the faulty PSU
233,234,235Power output over
temperature protection
-Ensure proper ambient temperature
236,237,238Overcurrent Protection of
Power Output
-Ensure proper ambient temperature
239Over voltage Protection of Power Output-Check the power supply within the power grid
240Low Voltage Protection for
Power Output
-Check the power supply within the power grid
241Power output current imbalance-Replace the faulty PSU
243,244,245Over-temperature Protection for Power Input-Ensure proper ambient temperature
246,247,248,
249,250,251
Overcurrent Protection for Power Input-Replace the faulty PSU
253,254Power Fan Error-Replace the faulty PSU
257Input over current protection of power supply
primary side
-Install a new PSU if restarting the miner does not work
263,264Power communication warning
Power communication error
-Check that the screws on the control board are properly tightened
267Power watchdog protection-Replace the faulty PSU
268,269Power output over-current protection-Ensure proper ambient temperature
270,271,
272,273
Power input over-voltage protection
Warning of excessive power output of power supply
-Ensure proper ambient temperature
274Power fan warning-Check the PSU’s rear power fan for blockage or failure; replace if needed
275Power over temperature warning-Ensure proper ambient temperature
300SM0 temperature sensor detection error-Check the connection of Hashboard 0 (the rightmost board when facing the miner’s front fan) is securely connected
301SM1 temperature sensor detection error-Check the connection of Hashboard 1 (center board) for proper connection
302SM2 temperature sensor detection error-Check the connection of Hashboard 2 (leftmost board when facing the miner’s front fan) is securely connected
320SM0 temperature reading
error
Check the connection between the control board and Hashboard 0 (the rightmost board when facing the miner’s front fan)
321SM1 temperature reading
error
Check the connection between the control board and Hashboard 1 (center board)
322SM2 temperature reading
error
Check the connection between the control board and Hashboard 2 (leftmost board when facing the miner’s front fan)
329Control board temperature
sensor communication error
-Ensure the control cable connection between the PSU and the control board is secure and not loose
-Make sure the hash board adapter cables are correctly connected to the control board.
350,351,252SM0, SM1, SM2 temperature protecting-Ensure proper ambient temperature
410, 420,
430, 440
SM0 detect eeprom error-Check the connection between the control board and hashboard 0.(the rightmost board when facing the miner’s front fan)
-If the issue persists, flash the EEPROM.
411, 421,
431, 441
SM1 detect eeprom error-Check the connection between the control board and hashboard 1.(center board)
-If the issue persists, flash the EEPROM.
412, 422,
432, 442
SM2 detect eeprom error-Check the connection between the control board and hashboard 2.(leftmost board when facing the miner’s front fan)
-If the issue persists, flash the EEPROM.
510SM0 miner type error-Verify the hashboard0 (the rightmost board when facing the miner’s front fan) version and type.
-If inconsistent, replace with the correct hashboard.
511SM1 miner type error-Verify the hashboard1 (center board) version and type.
-If inconsistent, replace with the correct hashboard.
512SM2 miner type error-Verify the hashboard2 (leftmost board when facing the miner’s front fan) version and type.
-If inconsistent, replace with the correct hashboard.
530,531,532-SM0, SM1, SM2 not found-Inspect the adapter board connection and arrangement.
-If issues persist, replace the control board.
540,550,560-SM0 reading chip id error
-SM0 loss balance
-Check for a faulty chip or component on the hashboard0 (the rightmost board when facing the miner’s front fan) version and type.
-Replace the defective chip or component if identified.
541,551,561-SM1 reading chip id error
-SM1 loss balance
-Check for a faulty chip or component on the hashboard1.(center board)
-Replace the defective chip or component if identified.
542,552,562-SM2 reading chip id error
-SM2 loss balance
-Check for a faulty chip or component on the hashboard2 ((leftmost board when facing the miner’s front fan).
-Replace the defective chip or component if identified.
600, 610Environment temperature is high-Ensure proper ambient temperature
710Control board rebooted as exception-Download the latest firmware and update.
800,801,802system-monitor checksum errorUpdate firmware
2010,2020,
2021,2022
Pool Connection Error-Verify and update the pool information with the correct settings.
-If the error persists, update the firmware to the latest version
2030High rejection rate of pool-Verify and update the pool information with the correct settings.
-If the error persists, update the firmware to the latest version
2040The pool does not support the asic boost mode-Verify and update the pool information with the correct settings.
-If the error persists, update the firmware to the latest version
5110,5111,5112Frequency Up TimeoutReboot
8410Software version errorUpdate the firmware to the latest version

Leave a Comment